X-Calculator
Math Updated November 23, 2026

Percent Error Calculator

Compare a measured value with the true value and get the percent, absolute and relative error.

Measured (experimental) value
Accepted (true) value
Advertisement
Advertisement

This percent error calculator measures how far an experimental or measured value is from the accepted (true) value, as a percentage of the true value. Enter both numbers to get the percent error, the signed error that shows whether you measured high or low, and the absolute and relative error — the figures a lab report usually asks for.

Percent error formula

percent error = |measured − accepted| ÷ |accepted| × 100

The absolute-value bars make percent error a positive number: it tells you how big the error is, not its direction. Many chemistry and physics courses also ask for the signed version, (measured − accepted) ÷ accepted × 100, where a negative result means your measurement came in below the true value.

How to calculate percent error step by step

  1. Subtract the accepted value from your measured value: 9.6 − 9.81 = −0.21.
  2. Take the absolute value: |−0.21| = 0.21. This is the absolute error, in the same units as the measurement (m/s² here).
  3. Divide by the accepted value: 0.21 ÷ 9.81 = 0.0214. This is the relative error, a pure number with no units.
  4. Multiply by 100: 0.0214 × 100 = 2.14%.

That is the default example in the calculator: a pendulum experiment that measured gravitational acceleration as 9.6 m/s² against the standard value of 9.81 m/s².

Advertisement
Advertisement

Worked examples

  • Boiling point: you measure water boiling at 101.3 °C at sea level; accepted value 100 °C. Error = 1.3 ÷ 100 × 100 = 1.3%.
  • Density of aluminum: measured 2.5 g/cm³, accepted 2.70 g/cm³. Error = 0.2 ÷ 2.7 × 100 = 7.41% (signed −7.41%, measured low).
  • Mass of a 50 g standard: scale reads 48 g. Error = 2 ÷ 50 × 100 = 4%.
  • Resistor check: a 100 Ω resistor reads 105 Ω. Error = 5 ÷ 100 × 100 = 5% — exactly at the limit of a ±5% gold-band tolerance.

What counts as a good percent error?

There is no universal cutoff; it depends on the instrument and the experiment. As a rough guide for teaching labs:

Percent error Typical interpretation
Under 1% Excellent — close to the precision of good lab equipment
1–5% Good for most high-school and intro college labs
5–10% Acceptable for rough methods (stopwatch timing, rulers)
Over 10% Look for a systematic error, a unit mistake or a faulty setup

Commercial tolerances are stated the same way: standard resistors are ±1% or ±5%, and US retail scales are held to tolerances set in NIST Handbook 44 by the NIST Office of Weights and Measures.

Sources of error

  • Systematic errors push every reading the same way — an uncalibrated scale, a thermometer that reads 0.5 °C high, ignoring air resistance. They show up as a consistent sign in the signed percent error.
  • Random errors scatter readings both ways — reaction time on a stopwatch, reading a meniscus. Averaging several trials (try the average calculator) reduces them.
  • Blunders — wrong units, misread digits, a calculation slip — often produce errors over 50%.

Accepted values often used in lab reports

Quantity Accepted value
Gravitational acceleration (standard) 9.80665 m/s² (often 9.81)
Boiling point of water at 1 atm 100 °C (212 °F)
Density of water at 4 °C 1.000 g/cm³
Density of aluminum 2.70 g/cm³
Density of copper 8.96 g/cm³
Speed of sound in air at 20 °C 343 m/s
Absolute zero −273.15 °C

How to reduce percent error

  • Calibrate instruments against a known standard before you start, and zero the balance.
  • Repeat each measurement at least three times and use the mean.
  • Measure larger quantities when you can: timing 10 pendulum swings and dividing by 10 cuts stopwatch error tenfold.
  • Keep full precision through the calculation and round only the final answer.

Percent error vs. percent difference vs. percent change

Use percent error when one value is a known true or reference value. Use percent difference when you compare two measurements and neither is more correct — it divides by their average. Use percent change when a quantity moves from an old value to a new one over time; the percentage change calculator gives both of the last two.

Frequently Asked Questions

How do you calculate percent error?

Subtract the accepted value from the measured value, take the absolute value, divide by the accepted value and multiply by 100. For 9.6 measured vs. 9.81 accepted: 0.21 ÷ 9.81 × 100 = 2.14%.

Can percent error be negative?

The standard formula uses absolute values, so percent error is never negative. The signed version can be negative, which simply means the measured value was lower than the accepted value.

What is a good percent error?

In most school labs, under 5% is considered good and under 1% excellent. Acceptable error ultimately depends on the precision of your instruments and method.

What is the difference between absolute error and percent error?

Absolute error is the raw difference in the measurement units, such as 0.21 m/s². Percent error divides that by the accepted value, so you can compare accuracy across different scales.

What if the accepted value is zero?

Percent error is undefined because you would divide by zero. In that case report the absolute error with its units.

Advertisement
Advertisement
Related

You may also need

All Math Calculators
Advertisement